LiveO2 Adaptive Contrast EWOT System for Home Oxygen Training
Authorized LiveO2 Dealer
Questions? Call Us: 888.488.8784
Free LiveO2 Set-up Support + New User Coaching (USA)
Personalized Purchase Assistance
Shipping
Shipping is calculated based on the selected system configuration and delivery location. LiveO2 systems ship from LaPorte, Colorado, USA.
Manufacturer Warranty
LiveO2 includes a 2-year standard manufacturer warranty, with an optional 4-year extended warranty. See Warranty Information below for current terms, hour limits, and exclusions.
Low-VOC reservoir materials and silicone tubing.
$5,075 - $6,650
LiveO2 Purchase Assistance
✔ Get clear answers on pricing, system options, and next steps.
✔ Start by speaking with a SanaVi Product Specialist. We’ll help you compare system options, understand pricing, and answer product questions. If you decide to move forward, your specialist will guide you through the next steps in the LiveO2 purchase process.
What Is the LiveO2 Adaptive Contrast EWOT System?
The LiveO2 Adaptive Contrast EWOT System is a single-user Exercise with Oxygen Therapy (EWOT) system that combines oxygen-rich breathing with simulated-altitude breathing during structured exercise. Designed for home gyms, athletic and performance environments, wellness studios, clinics, and other professional settings, it provides LiveO2 Adaptive Contrast training with a fixed simulated altitude of approximately 10,000 feet.
Unlike an oxygen-only EWOT system, the Adaptive Contrast System allows the user to switch between oxygen-rich air and reduced-oxygen simulated-altitude air without changing exercise equipment. Separate reservoir chambers keep both air environments available during the session, while the Adaptive Contrast switch controls movement between the two breathing phases.
Because it alternates oxygen-rich and reduced-oxygen conditions, the system is often discussed alongside intermittent hypoxic-hyperoxic training (IHHT), hypoxic hyperoxic training, and other forms of oxygen contrast training. The distinction is important: the LiveO2 Adaptive Contrast System is an active, exercise-based EWOT system rather than a conventional passive IHHT machine or IHHT device.
For buyers who want LiveO2 Adaptive Contrast but do not need adjustable simulated altitude, this system provides a streamlined fixed-altitude option with the same core oxygen-contrast training concept used throughout the LiveO2 Adaptive Contrast family.
Single-User Adaptive Contrast Training for Home and Professional Environments
The LiveO2 Adaptive Contrast System is built around one training station and can be used in dedicated home gyms, athletic and performance spaces, wellness studios, clinics, and other professional or commercial environments.
Its fixed 10,000-foot simulated-altitude setting keeps system operation straightforward while still providing both oxygen-rich and reduced-oxygen breathing phases. Users can follow supported Adaptive Contrast protocols at the 10,000-foot level without needing to select or adjust the simulated altitude between sessions.
For home users, this can provide a more accessible way to add oxygen contrast training to a structured exercise routine without moving into the adjustable-altitude capabilities of the Extreme. For professional settings, the fixed-altitude design may also suit facilities that want consistent single-user Adaptive Contrast sessions without requiring multiple altitude settings.
The primary difference between this system and the LiveO2 Extreme is altitude control. The Adaptive Contrast System remains fixed at approximately 10,000 feet, while the Extreme allows simulated altitude to be adjusted from approximately 10,000 to 22,000 feet.
Fixed 10,000-Foot Simulated Altitude & Hypoxic-Hyperoxic Training
The LiveO2 Adaptive Contrast System uses a fixed simulated altitude of approximately 10,000 feet for the reduced-oxygen portion of a session. During structured exercise, the user can switch between oxygen-rich air and simulated-altitude air through the Adaptive Contrast switch.
This alternating format places the system within the broader discussion around intermittent hypoxic-hyperoxic training, hypoxic hyperoxic training, IHHT training, oxygen contrast training, and EWOT-IHHT comparisons.
For buyers researching an IHHT machine, IHHT device, or LiveO2 IHHT system, the active-exercise component is an important distinction. LiveO2 Adaptive Contrast combines oxygen-rich and reduced-oxygen breathing with movement rather than functioning as a conventional passive IHHT system.
The fixed 10,000-foot setting supports the complete LiveO2 HIIT O₂ progression available at that altitude. Users who specifically want access to adjustable or higher simulated-altitude stages should compare the LiveO2 Extreme, which expands the altitude range to approximately 10,000–22,000 feet.
10 LPM Standard Output with 20 LPM Configuration Option
The LiveO2 Adaptive Contrast System is available in 10 LPM and 20 LPM air-supply configurations.
The standard 10 LPM configuration uses one 10 LPM air separator and has an approximate initial reservoir fill time of 56 minutes from empty.
The optional 20 LPM configuration uses two 10 LPM air separators, providing additional replenishment capacity and reducing the approximate initial fill time from empty to 28 minutes. This configuration may be useful for higher-use home environments, athletic households, wellness studios, clinics, and other settings where sessions may be scheduled closer together.
Both configurations retain the same single training station and fixed approximately 10,000-foot simulated altitude. Choosing 20 LPM does not create adjustable altitude, increase oxygen concentration, or add a second training station.
The oxygen chamber continues replenishing while the system operates, including during use. Initial filling from empty is therefore different from preparing an already-filled, operating system for another session.
Onboarding, Training Support, and Guided Training Resources
The LiveO2 Adaptive Contrast System includes owner access to the LiveO2 Training App along with New User Coaching to help customers become familiar with system setup, Adaptive Contrast switching, session structure, and available training protocols.
The LiveO2 Training App provides guided sessions, session timers, training history, progress tracking, and access to available training resources. Training programs may include Whole Body O₂, Post-Session Breathwork, Body Awareness, HIIT O₂, Altitude O₂, and VO₂ Max training, depending on program access, user readiness, system configuration, and LiveO2 guidance.
New User Coaching is included with qualifying system orders and is currently listed by LiveO2 as a $500 value. The coaching package is provided per qualifying order rather than separately for every user.
LiveO2 also provides phone or video assistance, video setup guidance, an instruction manual, support-portal access, and access to its private user community. Together, these resources provide a structured path for learning the system while helping users understand the distinction between fixed-altitude Adaptive Contrast and the adjustable-altitude capabilities available with the LiveO2 Extreme.
Explore more options in our Exercise With Oxygen Therapy (EWOT) Systems collection.
Choose options

What's Included
- One 10 LPM air separator — 10 LPM standard configuration
- 1 fixed-altitude Adaptive Contrast reservoir with a single training station
- 1 Adaptive Contrast switch
- 1 Standard Neoprene Mask Kit
- Selected wall/ceiling hanging hardware or freestanding frame kit
- 1 pulse oximeter
- Required breathing hose, silicone tubing, and connectors
- LiveO2 Training App owner access
- New User Coaching — $500 value, included at no charge
- Instruction manual and setup support
- Optional 20 LPM configuration with a second 10 LPM air separator for additional replenishment capacity and faster initial reservoir filling
Images may show this item in use with exercise equipment; only the items listed above are included in this product listing.


System Features
- Single-user Adaptive Contrast EWOT
- Fixed 10,000 ft simulated altitude
- Oxygen-rich / simulated-altitude phases
- Home, athletic, studio, clinic & professional use
- 10 LPM standard configuration
- Optional 20 LPM configuration
- 56-minute initial fill at 10 LPM
- 28-minute initial fill at 20 LPM
- Adaptive Contrast switch
- Standard Neoprene Mask Kit
- Hanging hardware or freestanding frame
- Pulse oximeter
- Breathing hose, silicone tubing & connectors
- LiveO2 Training App access
- New User Coaching included
- LiveO2 setup & support resources


EWOT / Adaptive Contrast Training Benefits
- Supports progressive oxygen-focused conditioning
- Adds simulated-altitude challenge to structured exercise sessions
- Supports training progression beyond oxygen-only exercise
- Supports endurance and performance-focused training goals
- Complements post-workout recovery routines
- Supports energy-focused wellness and conditioning routines
- Supports circulation-focused exercise and oxygen training
- Provides structured oxygen-contrast training for varied fitness and wellness goals
Compatible Accessories & User Manual(s)
10 LPM Air Separator Configuration:
The standard LiveO2 Adaptive Contrast EWOT System includes one 10 LPM air separator. LiveO2 currently lists an approximate initial reservoir fill time of 56 minutes from empty. The oxygen chamber continues replenishing while the system operates, including during use.
Adaptive Contrast Switch:
The included Adaptive Contrast switch allows the user to move between oxygen-rich and simulated-altitude breathing phases during structured Exercise with Oxygen Therapy (EWOT) and Adaptive Contrast sessions.
Fixed-Altitude Contrast Reservoir:
The system includes one contrast reservoir with a single training station. Separate reservoir chambers hold oxygen-rich and simulated-altitude air, with the altitude side fixed at approximately 10,000 feet.
Standard Neoprene Mask Kit:
The package includes one Standard Neoprene Mask Kit for use as the system’s breathing interface. Premium EWOT Mask Kits are available separately for customers who prefer an upgraded mask option.
Wall/Ceiling Hanging Hardware or Freestanding Frame Kit:
Customers can select the included wall/ceiling hanging hardware or a freestanding frame kit based on room layout, available space, and preferred installation style.
Pulse Oximeter:
One pulse oximeter is included for monitoring oxygen saturation and pulse rate during appropriate setup and structured training sessions.
Breathing Hose, Silicone Tubing, and Connectors:
The required breathing hose, silicone tubing, and connectors are included for connecting the air separator, reservoir, Adaptive Contrast components, and mask system.
LiveO2 Training App Owner Access:
The system includes owner access to the LiveO2 Training App, including guided sessions, session timers, training history, progress tracking, and access to available training resources.
Instruction Manual and Setup Support:
LiveO2 provides an instruction manual along with phone or video assistance, video setup guidance, support-portal access, and additional setup resources.
New User Coaching:
One New User Coaching package is included with a qualifying system order and is currently listed by LiveO2 as a $500 value. The coaching package is provided per qualifying order rather than separately for every user.
Optional 20 LPM Air-Supply Configuration:
The optional 20 LPM configuration adds a second 10 LPM air separator, increasing replenishment capacity and reducing the approximate initial reservoir fill time from 56 minutes to 28 minutes from empty. This can be useful for higher-use home environments, athletic households, wellness studios, clinics, and other settings where sessions may be scheduled closer together.
The 20 LPM configuration retains the same single training station and fixed approximately 10,000-foot simulated-altitude setting. It does not add adjustable altitude, increase oxygen concentration, or create a second training station.
Images may show this item in use with exercise equipment; only the items listed above are included in this product listing.
What’s Included
10 LPM Air Separator Configuration:
The standard LiveO2 Adaptive Contrast EWOT System includes one 10 LPM air separator. LiveO2 currently lists an approximate initial reservoir fill time of 56 minutes from empty. The oxygen chamber continues replenishing while the system operates, including during use.
Adaptive Contrast Switch:
The included Adaptive Contrast switch allows the user to move between oxygen-rich and simulated-altitude breathing phases during structured Exercise with Oxygen Therapy (EWOT) and Adaptive Contrast sessions.
Fixed-Altitude Contrast Reservoir:
The system includes one contrast reservoir with a single training station. Separate reservoir chambers hold oxygen-rich and simulated-altitude air, with the altitude side fixed at approximately 10,000 feet.
Standard Neoprene Mask Kit:
The package includes one Standard Neoprene Mask Kit for use as the system’s breathing interface. Premium EWOT Mask Kits are available separately for customers who prefer an upgraded mask option.
Wall/Ceiling Hanging Hardware or Freestanding Frame Kit:
Customers can select the included wall/ceiling hanging hardware or a freestanding frame kit based on room layout, available space, and preferred installation style.
Pulse Oximeter:
One pulse oximeter is included for monitoring oxygen saturation and pulse rate during appropriate setup and structured training sessions.
Breathing Hose, Silicone Tubing, and Connectors:
The required breathing hose, silicone tubing, and connectors are included for connecting the air separator, reservoir, Adaptive Contrast components, and mask system.
LiveO2 Training App Owner Access:
The system includes owner access to the LiveO2 Training App, including guided sessions, session timers, training history, progress tracking, and access to available training resources.
Instruction Manual and Setup Support:
LiveO2 provides an instruction manual along with phone or video assistance, video setup guidance, support-portal access, and additional setup resources.
New User Coaching:
One New User Coaching package is included with a qualifying system order and is currently listed by LiveO2 as a $500 value. The coaching package is provided per qualifying order rather than separately for every user.
Optional 20 LPM Air-Supply Configuration:
The optional 20 LPM configuration adds a second 10 LPM air separator, increasing replenishment capacity and reducing the approximate initial reservoir fill time from 56 minutes to 28 minutes from empty. This can be useful for higher-use home environments, athletic households, wellness studios, clinics, and other settings where sessions may be scheduled closer together.
The 20 LPM configuration retains the same single training station and fixed approximately 10,000-foot simulated-altitude setting. It does not add adjustable altitude, increase oxygen concentration, or create a second training station.
Images may show this item in use with exercise equipment; only the items listed above are included in this product listing.
Specifications, Configuration & Fit
System Type
LiveO2 Adaptive Contrast Exercise with Oxygen Therapy (EWOT) system for structured single-user oxygen training in home gyms, athletic and performance environments, wellness studios, clinics, and other professional or commercial settings.
Oxygen Training Method
Adaptive Contrast oxygen training with alternating oxygen-rich and simulated-altitude breathing phases. The user can switch between the two breathing environments during structured exercise sessions using the Adaptive Contrast switch.
Unlike the Extreme models, this system uses a fixed simulated-altitude setting rather than adjustable 10,000–22,000-foot altitude control.
User Capacity
Single-user system with one training station.
Both the 10 LPM and 20 LPM configurations retain the same single training station and fixed simulated-altitude setting.
Simulated Altitude / Hypoxic Challenge
Fixed simulated altitude: approximately 10,000 ft
The Adaptive Contrast System provides oxygen-rich and simulated-altitude switching at this fixed altitude setting. Buyers who want adjustable simulated altitude should compare the LiveO2 Extreme.
Air Separator Configuration
10 LPM standard configuration: 1 × 10 LPM air separator
20 LPM configuration: 2 × 10 LPM air separators
The 20 LPM configuration provides additional replenishment capacity and faster initial reservoir filling. It does not add adjustable altitude, increase oxygen concentration, or create a second training station.
Reservoir Fill Time
10 LPM configuration: approximately 56 minutes from empty
20 LPM configuration: approximately 28 minutes from empty
The oxygen chamber continues replenishing while the system operates, including during use. Initial filling from empty is different from preparing an already-filled, operating system for another session.
Reservoir Dimensions
Reservoir: approximately 96 in H × 57 in W when laid flat
Filled depth: approximately 36 in
These measurements describe the reservoir itself and do not include the freestanding frame.
Frame Dimensions
Freestanding frame configuration: approximately 8 ft 6 in H × 6 ft W × 3 ft D
The support frame and stabilizing legs extend beyond the reservoir itself.
Air Separator Dimensions
Each air separator: approximately 23.6 in H × 15 in W × 14.6 in D
Allow at least 8 in of open space on all sides of each air separator for ventilation.
The 10 LPM configuration uses one air separator; the 20 LPM configuration uses two.
Placement Requirements
Designed for indoor home or professional use with adequate space for the reservoir, selected air-separator configuration, breathing hose, tubing, mask system, exercise equipment, and safe movement around the training area.
For wall or ceiling installation, hanging points should be spaced approximately 4 ft 6 in apart, with at least 8 in between the reservoir and the wall so the reservoir can fill freely.
Allow additional space for a bike or other compatible exercise equipment and a clear path around the training area.
Adaptive Contrast Control
Includes an Adaptive Contrast switch that allows the user to move between oxygen-rich and simulated-altitude breathing phases during exercise without changing equipment.
Mask System
Includes one Standard Neoprene Mask Kit.
Premium EWOT Mask Kits are available separately in Extra Small, Small, Medium, and Large sizes for customers who prefer an upgraded mask option.
Airflow / Pressure Design
LiveO2 uses a neutral-pressure breathing system rather than positive-pressure breathing assistance. The user breathes naturally through the system while the Adaptive Contrast switch controls access to oxygen-rich or simulated-altitude air.
Power Requirements
U.S. ordering configuration: 110V / 60 Hz
LiveO2’s current user guide specifies connection to a standard 120V / 60 Hz grounded outlet. Each air separator draws approximately 6 amps / 450 watts.
International ordering configurations: 110V / 60 Hz or 220V / 50 Hz, depending on destination.
LiveO2 currently uses both 110V and 120V terminology in its official materials. Customers should select the appropriate power configuration for their location when ordering.
Included Support
Includes LiveO2 Training App owner access and one New User Coaching package with a qualifying system order.
Additional support includes phone or video assistance, video setup guidance, an instruction manual, support-portal access, and access to the private LiveO2 user community.
Shipping
Shipping costs vary based on the selected system configuration and delivery location. LiveO2 systems ship from LaPorte, Colorado, USA.
International orders may require additional lead time and equipment configuration based on regional electrical requirements.
Warranty
Standard Manufacturer Warranty: 2 years
Optional Extended Warranty: 4 years
For current coverage terms, usage-hour limits, exclusions, and claim requirements, please review LiveO2’s applicable Standard Warranty and Extended Warranty information.
Reservoir Materials & Low-VOC Liner Design
LiveO2 reservoir construction is designed with the breathing pathway in mind. The reservoir uses a thin oxygen-retaining liner to reduce unnecessary plastic exposure, along with a woven nylon protective shell for durability and a low-VOC inner liner. LiveO2 reservoir materials are tested clean below 3 parts per million, and the system uses biologically inert silicone tubing rather than PVC in the breathing pathway.
Inspection-Friendly, Non-Pressurized Reservoir Design
LiveO2 reservoirs use a white exterior to support easier visual inspection and include a zipper with an inspection/drainage port for internal inspection, rapid drainage, and care access when needed. The reservoir is designed to avoid sealed pressurization, allowing excess gas to escape rather than trapping gases inside the air compartment.
The LiveO2 Adaptive Contrast EWOT System is available in 10 LPM and 20 LPM configurations. The standard 10 LPM configuration uses one air separator and has an approximate initial reservoir fill time of 56 minutes from empty. The optional 20 LPM configuration uses two 10 LPM air separators, increasing replenishment capacity and reducing the approximate initial fill time to 28 minutes from empty.
The 20 LPM configuration may be especially useful for higher-use home environments, athletic households, wellness studios, clinics, gyms, and other professional settings where sessions may be scheduled more frequently.
Both configurations retain the same single training station and fixed approximately 10,000-foot simulated-altitude setting. Customers can also choose between a wall/ceiling hanging installation or a freestanding frame configuration based on room layout, available space, and preferred installation style.
The LiveO2 Adaptive Contrast EWOT System is designed for indoor home gyms, athletic and performance environments, wellness studios, clinics, gyms, and other professional settings. Space requirements depend on the selected reservoir installation method and the exercise equipment used during sessions.
The Adaptive Contrast reservoir measures approximately 96 inches high × 57 inches wide when laid flat and has an approximate filled depth of 36 inches. When using the freestanding frame configuration, plan for approximately 8 ft 6 in high × 6 ft wide × 3 ft deep.
Allow additional space for the selected 10 LPM or 20 LPM air-separator configuration, breathing hose, silicone tubing, mask connection, user movement, and compatible exercise equipment such as a bike, treadmill, rebounder, or other training equipment.
Each LiveO2 air separator measures approximately 23.6 inches high × 15 inches wide × 14.6 inches deep and should have at least 8 inches of open space on all sides for proper ventilation.
For wall or ceiling installations, hanging points should be spaced approximately 4 ft 6 in apart, with at least 8 inches between the reservoir and the wall so the reservoir can fill freely.
Technical Specifications
System Type
LiveO2 Adaptive Contrast Exercise with Oxygen Therapy (EWOT) system for structured single-user oxygen training in home gyms, athletic and performance environments, wellness studios, clinics, and other professional or commercial settings.
Oxygen Training Method
Adaptive Contrast oxygen training with alternating oxygen-rich and simulated-altitude breathing phases. The user can switch between the two breathing environments during structured exercise sessions using the Adaptive Contrast switch.
Unlike the Extreme models, this system uses a fixed simulated-altitude setting rather than adjustable 10,000–22,000-foot altitude control.
User Capacity
Single-user system with one training station.
Both the 10 LPM and 20 LPM configurations retain the same single training station and fixed simulated-altitude setting.
Simulated Altitude / Hypoxic Challenge
Fixed simulated altitude: approximately 10,000 ft
The Adaptive Contrast System provides oxygen-rich and simulated-altitude switching at this fixed altitude setting. Buyers who want adjustable simulated altitude should compare the LiveO2 Extreme.
Air Separator Configuration
10 LPM standard configuration: 1 × 10 LPM air separator
20 LPM configuration: 2 × 10 LPM air separators
The 20 LPM configuration provides additional replenishment capacity and faster initial reservoir filling. It does not add adjustable altitude, increase oxygen concentration, or create a second training station.
Reservoir Fill Time
10 LPM configuration: approximately 56 minutes from empty
20 LPM configuration: approximately 28 minutes from empty
The oxygen chamber continues replenishing while the system operates, including during use. Initial filling from empty is different from preparing an already-filled, operating system for another session.
Reservoir Dimensions
Reservoir: approximately 96 in H × 57 in W when laid flat
Filled depth: approximately 36 in
These measurements describe the reservoir itself and do not include the freestanding frame.
Frame Dimensions
Freestanding frame configuration: approximately 8 ft 6 in H × 6 ft W × 3 ft D
The support frame and stabilizing legs extend beyond the reservoir itself.
Air Separator Dimensions
Each air separator: approximately 23.6 in H × 15 in W × 14.6 in D
Allow at least 8 in of open space on all sides of each air separator for ventilation.
The 10 LPM configuration uses one air separator; the 20 LPM configuration uses two.
Placement Requirements
Designed for indoor home or professional use with adequate space for the reservoir, selected air-separator configuration, breathing hose, tubing, mask system, exercise equipment, and safe movement around the training area.
For wall or ceiling installation, hanging points should be spaced approximately 4 ft 6 in apart, with at least 8 in between the reservoir and the wall so the reservoir can fill freely.
Allow additional space for a bike or other compatible exercise equipment and a clear path around the training area.
Adaptive Contrast Control
Includes an Adaptive Contrast switch that allows the user to move between oxygen-rich and simulated-altitude breathing phases during exercise without changing equipment.
Mask System
Includes one Standard Neoprene Mask Kit.
Premium EWOT Mask Kits are available separately in Extra Small, Small, Medium, and Large sizes for customers who prefer an upgraded mask option.
Airflow / Pressure Design
LiveO2 uses a neutral-pressure breathing system rather than positive-pressure breathing assistance. The user breathes naturally through the system while the Adaptive Contrast switch controls access to oxygen-rich or simulated-altitude air.
Power Requirements
U.S. ordering configuration: 110V / 60 Hz
LiveO2’s current user guide specifies connection to a standard 120V / 60 Hz grounded outlet. Each air separator draws approximately 6 amps / 450 watts.
International ordering configurations: 110V / 60 Hz or 220V / 50 Hz, depending on destination.
LiveO2 currently uses both 110V and 120V terminology in its official materials. Customers should select the appropriate power configuration for their location when ordering.
Included Support
Includes LiveO2 Training App owner access and one New User Coaching package with a qualifying system order.
Additional support includes phone or video assistance, video setup guidance, an instruction manual, support-portal access, and access to the private LiveO2 user community.
Shipping
Shipping costs vary based on the selected system configuration and delivery location. LiveO2 systems ship from LaPorte, Colorado, USA.
International orders may require additional lead time and equipment configuration based on regional electrical requirements.
Warranty
Standard Manufacturer Warranty: 2 years
Optional Extended Warranty: 4 years
For current coverage terms, usage-hour limits, exclusions, and claim requirements, please review LiveO2’s applicable Standard Warranty and Extended Warranty information.
Product Materials & Design Notes
Reservoir Materials & Low-VOC Liner Design
LiveO2 reservoir construction is designed with the breathing pathway in mind. The reservoir uses a thin oxygen-retaining liner to reduce unnecessary plastic exposure, along with a woven nylon protective shell for durability and a low-VOC inner liner. LiveO2 reservoir materials are tested clean below 3 parts per million, and the system uses biologically inert silicone tubing rather than PVC in the breathing pathway.
Inspection-Friendly, Non-Pressurized Reservoir Design
LiveO2 reservoirs use a white exterior to support easier visual inspection and include a zipper with an inspection/drainage port for internal inspection, rapid drainage, and care access when needed. The reservoir is designed to avoid sealed pressurization, allowing excess gas to escape rather than trapping gases inside the air compartment.
Available Configurations
The LiveO2 Adaptive Contrast EWOT System is available in 10 LPM and 20 LPM configurations. The standard 10 LPM configuration uses one air separator and has an approximate initial reservoir fill time of 56 minutes from empty. The optional 20 LPM configuration uses two 10 LPM air separators, increasing replenishment capacity and reducing the approximate initial fill time to 28 minutes from empty.
The 20 LPM configuration may be especially useful for higher-use home environments, athletic households, wellness studios, clinics, gyms, and other professional settings where sessions may be scheduled more frequently.
Both configurations retain the same single training station and fixed approximately 10,000-foot simulated-altitude setting. Customers can also choose between a wall/ceiling hanging installation or a freestanding frame configuration based on room layout, available space, and preferred installation style.
Fit & Space Requirements
The LiveO2 Adaptive Contrast EWOT System is designed for indoor home gyms, athletic and performance environments, wellness studios, clinics, gyms, and other professional settings. Space requirements depend on the selected reservoir installation method and the exercise equipment used during sessions.
The Adaptive Contrast reservoir measures approximately 96 inches high × 57 inches wide when laid flat and has an approximate filled depth of 36 inches. When using the freestanding frame configuration, plan for approximately 8 ft 6 in high × 6 ft wide × 3 ft deep.
Allow additional space for the selected 10 LPM or 20 LPM air-separator configuration, breathing hose, silicone tubing, mask connection, user movement, and compatible exercise equipment such as a bike, treadmill, rebounder, or other training equipment.
Each LiveO2 air separator measures approximately 23.6 inches high × 15 inches wide × 14.6 inches deep and should have at least 8 inches of open space on all sides for proper ventilation.
For wall or ceiling installations, hanging points should be spaced approximately 4 ft 6 in apart, with at least 8 inches between the reservoir and the wall so the reservoir can fill freely.
Warranty, Support & Safety
LiveO2 provides a limited manufacturer warranty for the original purchaser covering qualifying defects in materials or workmanship.
Standard Manufacturer Warranty: 2 years
Optional Extended Warranty: 4 years
Masks, pulse oximeters, breather hoses, shipping responsibilities, exclusions, and claim procedures are subject to LiveO2’s current manufacturer warranty terms and may be handled differently from primary system components.
Customers should review LiveO2’s current warranty terms for the applicable usage-hour limits, covered components, exclusions, shipping responsibilities, and claim requirements at the time of purchase.
Please see the SanaVi Warranty Policy Page for further details and information.
Coaching, Training Support, and Guided Training Resources
LiveO2 provides setup, training, and ongoing support resources for Adaptive Contrast System owners. Included support currently features owner access to the LiveO2 Training App, New User Coaching, phone or video assistance, video setup guidance, an instruction manual, access to the LiveO2 support portal, and the private LiveO2 user community.
The LiveO2 Training App provides guided sessions, session timers, training history, progress tracking, and access to available training resources. New User Coaching helps customers become familiar with system setup, Adaptive Contrast switching, oxygen-rich and simulated-altitude breathing phases, pulse oximeter use, session structure, and appropriate training progression.
LiveO2’s support resources also include setup and operating documentation covering reservoir installation, air-separator connections, mask use, cleaning, maintenance, troubleshooting, and general system operation. Customers can use the LiveO2 support portal or contact the manufacturer when additional technical assistance is needed.
Additional coaching, practitioner education, certification, or advanced training resources may also be available separately. These resources can help users better understand the system’s fixed approximately 10,000-foot simulated-altitude setting, Adaptive Contrast switching, available training protocols, and appropriate session progression.
The LiveO2 Adaptive Contrast EWOT System uses alternating oxygen-rich and simulated-altitude breathing phases and should be used only after reviewing LiveO2’s current setup instructions, safety warnings, training guidance, and manufacturer recommendations.
LiveO2 recommends completing its included New User Coaching and training resources before beginning structured Adaptive Contrast sessions. Users should follow current manufacturer guidance for system setup, pulse oximeter use, session structure, and appropriate training progression.
LiveO2 states that its products are intended for healthy adults participating in exercise training and recommends consulting a qualified healthcare professional before beginning an exercise program. Individuals with a health condition should seek healthcare guidance before altitude training.
For important health and safety information, please review SanaVi's Medical & Safety Disclaimer Page before using this equipment.
Warranty Information
LiveO2 provides a limited manufacturer warranty for the original purchaser covering qualifying defects in materials or workmanship.
Standard Manufacturer Warranty: 2 years
Optional Extended Warranty: 4 years
Masks, pulse oximeters, breather hoses, shipping responsibilities, exclusions, and claim procedures are subject to LiveO2’s current manufacturer warranty terms and may be handled differently from primary system components.
Customers should review LiveO2’s current warranty terms for the applicable usage-hour limits, covered components, exclusions, shipping responsibilities, and claim requirements at the time of purchase.
Please see the SanaVi Warranty Policy Page for further details and information.
Support, Service & Safety
Coaching, Training Support, and Guided Training Resources
LiveO2 provides setup, training, and ongoing support resources for Adaptive Contrast System owners. Included support currently features owner access to the LiveO2 Training App, New User Coaching, phone or video assistance, video setup guidance, an instruction manual, access to the LiveO2 support portal, and the private LiveO2 user community.
The LiveO2 Training App provides guided sessions, session timers, training history, progress tracking, and access to available training resources. New User Coaching helps customers become familiar with system setup, Adaptive Contrast switching, oxygen-rich and simulated-altitude breathing phases, pulse oximeter use, session structure, and appropriate training progression.
LiveO2’s support resources also include setup and operating documentation covering reservoir installation, air-separator connections, mask use, cleaning, maintenance, troubleshooting, and general system operation. Customers can use the LiveO2 support portal or contact the manufacturer when additional technical assistance is needed.
Additional coaching, practitioner education, certification, or advanced training resources may also be available separately. These resources can help users better understand the system’s fixed approximately 10,000-foot simulated-altitude setting, Adaptive Contrast switching, available training protocols, and appropriate session progression.
Medical Disclaimer(s)
The LiveO2 Adaptive Contrast EWOT System uses alternating oxygen-rich and simulated-altitude breathing phases and should be used only after reviewing LiveO2’s current setup instructions, safety warnings, training guidance, and manufacturer recommendations.
LiveO2 recommends completing its included New User Coaching and training resources before beginning structured Adaptive Contrast sessions. Users should follow current manufacturer guidance for system setup, pulse oximeter use, session structure, and appropriate training progression.
LiveO2 states that its products are intended for healthy adults participating in exercise training and recommends consulting a qualified healthcare professional before beginning an exercise program. Individuals with a health condition should seek healthcare guidance before altitude training.
For important health and safety information, please review SanaVi's Medical & Safety Disclaimer Page before using this equipment.
Product FAQs
What is the LiveO2 Adaptive Contrast EWOT System?
The LiveO2 Adaptive Contrast EWOT System is a single-user Exercise with Oxygen Therapy (EWOT) system for home gyms, athletic and performance environments, wellness studios, clinics, and other professional settings. It combines oxygen-rich breathing with simulated-altitude breathing during structured exercise and uses a fixed simulated-altitude setting of approximately 10,000 feet.
How does the LiveO2 Adaptive Contrast System work?
The system allows the user to switch between oxygen-rich air and reduced-oxygen simulated-altitude air during exercise. Separate reservoir chambers hold both breathing environments, and the Adaptive Contrast switch lets the user move between them during a guided session.
What is the LiveO2 Air Separator, and is it the same as an oxygen concentrator?
The LiveO2 Air Separator produces the oxygen-rich and reduced-oxygen air used by the Adaptive Contrast system. LiveO2 uses the term Air Separator because the component supports both sides of the oxygen-contrast training process rather than functioning as a conventional medical oxygen concentrator.
What is the difference between LiveO2 Adaptive Contrast and LiveO2 Extreme?
The primary difference is simulated-altitude control. The Adaptive Contrast System uses a fixed simulated altitude of approximately 10,000 feet, while the LiveO2 Extreme provides adjustable simulated altitude from approximately 10,000 to 22,000 feet.
What is the difference between oxygen-reduced air and adjustable simulated-altitude control?
Oxygen-reduced air is the lower-oxygen breathing phase used during Adaptive Contrast training. Adjustable simulated-altitude control refers to the Extreme model’s ability to change the intensity of that altitude challenge.
The Adaptive Contrast System provides oxygen-rich and simulated-altitude switching at a fixed approximately 10,000-foot setting, while the Extreme allows the simulated altitude to be adjusted across a wider range.
What is the difference between 10 LPM and 20 LPM on the LiveO2 Adaptive Contrast System?
The 10 LPM configuration uses one 10 LPM air separator and has an approximate initial reservoir fill time of 56 minutes from empty.
The 20 LPM configuration uses two 10 LPM air separators, providing greater replenishment capacity and reducing the approximate initial fill time from empty to 28 minutes.
Both configurations have one training station and the same fixed approximately 10,000-foot simulated-altitude setting. Choosing 20 LPM does not add adjustable altitude or a second training station.
Is the LiveO2 Adaptive Contrast EWOT System designed for home and professional use?
Yes. The LiveO2 Adaptive Contrast System can be used in dedicated home gyms and wellness spaces as well as athletic facilities, performance environments, wellness studios, clinics, and other professional settings.
LiveO2 currently positions this model as the lower-cost fixed-altitude entry point into Adaptive Contrast training. Buyers who specifically want adjustable simulated altitude should compare the LiveO2 Extreme.
Does the LiveO2 Adaptive Contrast System include coaching and training support?
Yes. The system includes owner access to the LiveO2 Training App and one New User Coaching package with a qualifying system order.
The Training App provides guided sessions, session timers, training history, progress tracking, and access to available training resources. LiveO2 also provides phone or video assistance, video setup guidance, an instruction manual, support-portal access, and access to its private user community.
The LiveO2 Adaptive Contrast EWOT System is set up by positioning the fixed-altitude contrast reservoir using the selected wall/ceiling hanging hardware or freestanding frame configuration, connecting the selected 10 LPM or 20 LPM air-separator setup, attaching the required breathing hose, silicone tubing, connectors, and Adaptive Contrast components, and preparing the Standard Neoprene Mask Kit for use with compatible exercise equipment.
The system should be used indoors with adequate space for the reservoir, air separator configuration, tubing pathways, exercise equipment, user access, and safe movement around the training area.
Before beginning structured sessions, users should review the current LiveO2 user manual, complete the included New User Coaching, and follow LiveO2 setup and training guidance. Users should become familiar with Adaptive Contrast switching, the fixed approximately 10,000-foot simulated-altitude setting, pulse oximeter use, session structure, and appropriate training progression.
The LiveO2 Adaptive Contrast EWOT System should be maintained according to LiveO2’s current cleaning and maintenance instructions. Masks should be cleaned after each use, and the breathing hose should be cleaned approximately monthly or whenever contamination is suspected.
After each session, disconnect the mask from the breathing hose, clean and dry the mask before storage, and loosely coil the breathing hose to help prevent kinking. Store masks, hoses, and other accessories in a clean, dry indoor location.
Keep the air separator ventilation areas unobstructed. LiveO2 recommends cleaning the external gross-particle filter weekly and inspecting or servicing internal intake filters according to accumulated operating hours.
For shared-use environments, each user should ideally have a dedicated mask or inner mask body, and cleaning practices should be followed carefully between users.
Do not attempt internal service of the air separator. Repairs or maintenance beyond routine owner care should be handled according to LiveO2 technical-support guidance.
General Questions
What is the LiveO2 Adaptive Contrast EWOT System?
The LiveO2 Adaptive Contrast EWOT System is a single-user Exercise with Oxygen Therapy (EWOT) system for home gyms, athletic and performance environments, wellness studios, clinics, and other professional settings. It combines oxygen-rich breathing with simulated-altitude breathing during structured exercise and uses a fixed simulated-altitude setting of approximately 10,000 feet.
How does the LiveO2 Adaptive Contrast System work?
The system allows the user to switch between oxygen-rich air and reduced-oxygen simulated-altitude air during exercise. Separate reservoir chambers hold both breathing environments, and the Adaptive Contrast switch lets the user move between them during a guided session.
What is the LiveO2 Air Separator, and is it the same as an oxygen concentrator?
The LiveO2 Air Separator produces the oxygen-rich and reduced-oxygen air used by the Adaptive Contrast system. LiveO2 uses the term Air Separator because the component supports both sides of the oxygen-contrast training process rather than functioning as a conventional medical oxygen concentrator.
What is the difference between LiveO2 Adaptive Contrast and LiveO2 Extreme?
The primary difference is simulated-altitude control. The Adaptive Contrast System uses a fixed simulated altitude of approximately 10,000 feet, while the LiveO2 Extreme provides adjustable simulated altitude from approximately 10,000 to 22,000 feet.
What is the difference between oxygen-reduced air and adjustable simulated-altitude control?
Oxygen-reduced air is the lower-oxygen breathing phase used during Adaptive Contrast training. Adjustable simulated-altitude control refers to the Extreme model’s ability to change the intensity of that altitude challenge.
The Adaptive Contrast System provides oxygen-rich and simulated-altitude switching at a fixed approximately 10,000-foot setting, while the Extreme allows the simulated altitude to be adjusted across a wider range.
What is the difference between 10 LPM and 20 LPM on the LiveO2 Adaptive Contrast System?
The 10 LPM configuration uses one 10 LPM air separator and has an approximate initial reservoir fill time of 56 minutes from empty.
The 20 LPM configuration uses two 10 LPM air separators, providing greater replenishment capacity and reducing the approximate initial fill time from empty to 28 minutes.
Both configurations have one training station and the same fixed approximately 10,000-foot simulated-altitude setting. Choosing 20 LPM does not add adjustable altitude or a second training station.
Is the LiveO2 Adaptive Contrast EWOT System designed for home and professional use?
Yes. The LiveO2 Adaptive Contrast System can be used in dedicated home gyms and wellness spaces as well as athletic facilities, performance environments, wellness studios, clinics, and other professional settings.
LiveO2 currently positions this model as the lower-cost fixed-altitude entry point into Adaptive Contrast training. Buyers who specifically want adjustable simulated altitude should compare the LiveO2 Extreme.
Does the LiveO2 Adaptive Contrast System include coaching and training support?
Yes. The system includes owner access to the LiveO2 Training App and one New User Coaching package with a qualifying system order.
The Training App provides guided sessions, session timers, training history, progress tracking, and access to available training resources. LiveO2 also provides phone or video assistance, video setup guidance, an instruction manual, support-portal access, and access to its private user community.
Usage & Setup
The LiveO2 Adaptive Contrast EWOT System is set up by positioning the fixed-altitude contrast reservoir using the selected wall/ceiling hanging hardware or freestanding frame configuration, connecting the selected 10 LPM or 20 LPM air-separator setup, attaching the required breathing hose, silicone tubing, connectors, and Adaptive Contrast components, and preparing the Standard Neoprene Mask Kit for use with compatible exercise equipment.
The system should be used indoors with adequate space for the reservoir, air separator configuration, tubing pathways, exercise equipment, user access, and safe movement around the training area.
Before beginning structured sessions, users should review the current LiveO2 user manual, complete the included New User Coaching, and follow LiveO2 setup and training guidance. Users should become familiar with Adaptive Contrast switching, the fixed approximately 10,000-foot simulated-altitude setting, pulse oximeter use, session structure, and appropriate training progression.
Maintenance & Care
The LiveO2 Adaptive Contrast EWOT System should be maintained according to LiveO2’s current cleaning and maintenance instructions. Masks should be cleaned after each use, and the breathing hose should be cleaned approximately monthly or whenever contamination is suspected.
After each session, disconnect the mask from the breathing hose, clean and dry the mask before storage, and loosely coil the breathing hose to help prevent kinking. Store masks, hoses, and other accessories in a clean, dry indoor location.
Keep the air separator ventilation areas unobstructed. LiveO2 recommends cleaning the external gross-particle filter weekly and inspecting or servicing internal intake filters according to accumulated operating hours.
For shared-use environments, each user should ideally have a dedicated mask or inner mask body, and cleaning practices should be followed carefully between users.
Do not attempt internal service of the air separator. Repairs or maintenance beyond routine owner care should be handled according to LiveO2 technical-support guidance.
Shipping, Delivery & Installation
LiveO2 shipping costs vary based on the customer’s delivery location, shipment size, number of boxes, and selected system configuration. Orders ship from LaPorte, Colorado.
Most orders ship within 24 hours after being placed, although some orders may take up to 72 hours to ship. Orders placed on weekends or holidays ship no earlier than the next business day. If an order is not expected to ship within 72 hours, a LiveO2 representative may contact the customer with an updated shipping timeframe.
Once an order ships, customers receive a shipping confirmation email from LiveO2 containing tracking information and an estimated delivery date.
International orders may require additional lead time, particularly when air separators must be configured for regional voltage and frequency requirements. Additional shipping charges, duties, taxes, or customs-related fees may also apply.
- Most LiveO2 orders ship within 24 hours, though some orders may take up to 72 hours to ship.
- Orders ship from LaPorte, Colorado.
- Orders placed on weekends or holidays ship no earlier than the next business day.
- If an order is not expected to ship within 72 hours, a LiveO2 representative may contact the customer with updated timing.
- Tracking information is emailed once the order ships, allowing customers to monitor shipment status and estimated delivery date.
- Shipping costs vary based on delivery location, shipment size, number of boxes, and selected system configuration.
- International orders may require additional lead time, especially when an air separator must be configured for regional voltage and frequency requirements.
- For complete information about shipping, delivery, freight inspection, and damage reporting, please review our Shipping, Delivery & Damage page.
LiveO2 provides installation and setup support for the Adaptive Contrast System through phone or video assistance, video setup guidance, the instruction manual, the LiveO2 support portal, owner access to the LiveO2 Training App, and included New User Coaching.
Before installation, customers should review LiveO2’s current setup instructions and confirm the appropriate reservoir mounting arrangement for their space. The Adaptive Contrast System is installed by positioning the fixed-altitude contrast reservoir using the selected wall/ceiling hanging hardware or freestanding frame configuration; connecting the selected 10 LPM or 20 LPM air-separator setup; attaching the required breathing hose, silicone tubing, connectors, and Adaptive Contrast components; and preparing the Standard Neoprene Mask Kit according to LiveO2 guidance.
Customers should also allow adequate space for the reservoir, air separator configuration, exercise equipment, tubing pathways, user access, and safe movement around the system. Each air separator should be placed on the floor with at least 8 inches of open space on all sides for ventilation.
The included New User Coaching and Training App resources help owners become familiar with system setup, Adaptive Contrast switching, pulse oximeter use, the fixed approximately 10,000-foot simulated-altitude setting, session structure, and appropriate training progression.
Shipping & Freight
LiveO2 shipping costs vary based on the customer’s delivery location, shipment size, number of boxes, and selected system configuration. Orders ship from LaPorte, Colorado.
Most orders ship within 24 hours after being placed, although some orders may take up to 72 hours to ship. Orders placed on weekends or holidays ship no earlier than the next business day. If an order is not expected to ship within 72 hours, a LiveO2 representative may contact the customer with an updated shipping timeframe.
Once an order ships, customers receive a shipping confirmation email from LiveO2 containing tracking information and an estimated delivery date.
International orders may require additional lead time, particularly when air separators must be configured for regional voltage and frequency requirements. Additional shipping charges, duties, taxes, or customs-related fees may also apply.
Delivery Expectations
- Most LiveO2 orders ship within 24 hours, though some orders may take up to 72 hours to ship.
- Orders ship from LaPorte, Colorado.
- Orders placed on weekends or holidays ship no earlier than the next business day.
- If an order is not expected to ship within 72 hours, a LiveO2 representative may contact the customer with updated timing.
- Tracking information is emailed once the order ships, allowing customers to monitor shipment status and estimated delivery date.
- Shipping costs vary based on delivery location, shipment size, number of boxes, and selected system configuration.
- International orders may require additional lead time, especially when an air separator must be configured for regional voltage and frequency requirements.
- For complete information about shipping, delivery, freight inspection, and damage reporting, please review our Shipping, Delivery & Damage page.
Installation & Setup
LiveO2 provides installation and setup support for the Adaptive Contrast System through phone or video assistance, video setup guidance, the instruction manual, the LiveO2 support portal, owner access to the LiveO2 Training App, and included New User Coaching.
Before installation, customers should review LiveO2’s current setup instructions and confirm the appropriate reservoir mounting arrangement for their space. The Adaptive Contrast System is installed by positioning the fixed-altitude contrast reservoir using the selected wall/ceiling hanging hardware or freestanding frame configuration; connecting the selected 10 LPM or 20 LPM air-separator setup; attaching the required breathing hose, silicone tubing, connectors, and Adaptive Contrast components; and preparing the Standard Neoprene Mask Kit according to LiveO2 guidance.
Customers should also allow adequate space for the reservoir, air separator configuration, exercise equipment, tubing pathways, user access, and safe movement around the system. Each air separator should be placed on the floor with at least 8 inches of open space on all sides for ventilation.
The included New User Coaching and Training App resources help owners become familiar with system setup, Adaptive Contrast switching, pulse oximeter use, the fixed approximately 10,000-foot simulated-altitude setting, session structure, and appropriate training progression.
Financing, Payments & Returns
LiveO2 offers financing options for qualifying customers. Financing availability depends on the provider, the applicant, and approval requirements. Customers should review current rates, fees, repayment terms, and eligibility requirements before applying.
Return and cancellation terms for LiveO2 systems are manufacturer-specific and may differ from SanaVi Health Systems’ standard return policy.
Customers should review the applicable return and cancellation terms before purchase and contact a SanaVi Product Specialist with any questions regarding eligibility, cancellation timing, return requirements, or the applicable process for their selected LiveO2 system.
Payment Options
LiveO2 offers financing options for qualifying customers. Financing availability depends on the provider, the applicant, and approval requirements. Customers should review current rates, fees, repayment terms, and eligibility requirements before applying.
Returns & Cancellations
Return and cancellation terms for LiveO2 systems are manufacturer-specific and may differ from SanaVi Health Systems’ standard return policy.
Customers should review the applicable return and cancellation terms before purchase and contact a SanaVi Product Specialist with any questions regarding eligibility, cancellation timing, return requirements, or the applicable process for their selected LiveO2 system.
Manufacturer & Regulatory Disclosures
LiveO2 was founded by electrical engineer Mark Squibb after health challenges affecting his family led him to investigate oxygen delivery and the limitations of conventional oxygen approaches. What began as an engineer-led effort to solve a practical problem eventually developed into an oxygen training company built around Adaptive Contrast, a method that alternates oxygen-rich and simulated-altitude breathing phases during structured exercise. LiveO2 presents its development as a process shaped by engineering, real-world testing, user experience, and continued refinement of its oxygen training systems.
Today, LiveO2 manufactures specialized oxygen training systems for home users, athletes, wellness-focused individuals, and professional environments such as clinics, studios, gyms, and performance facilities. The company supports its systems with the LiveO2 Training App, New User Coaching, setup guidance, instructional resources, protocol training, technical support, and customer care.
For SanaVi Health Systems, LiveO2 represents an important part of the Exercise with Oxygen Therapy category because its Adaptive Contrast technology expands beyond oxygen-only EWOT by incorporating alternating oxygen-rich and simulated-altitude breathing within structured exercise sessions.
We make every reasonable effort to keep product information accurate. Because some products are updated or fulfilled directly by the manufacturer, specifications, included components, packaging, images, or minor design details may change without notice. If a material change affects an order, SanaVi will review the matter in good faith and work toward a reasonable resolution.
For more information, please see the Manufacturer Product Updates & Specification Changes section of our Terms of Service.
LiveO2 positions its Adaptive Contrast EWOT systems around structured exercise, oxygen-rich breathing, simulated-altitude breathing phases, and general wellness and fitness applications. These systems are designed for Exercise with Oxygen Therapy (EWOT) and Adaptive Contrast training and are not intended for medical diagnosis, disease treatment, or medical oxygen use.
LiveO2 states that its systems are not intended to diagnose, treat, cure, prevent, or mitigate any disease or medical condition. LiveO2 identifies its products as exercise equipment rather than medical devices, and its current user guidance states that LiveO2 claims have not been evaluated by the U.S. Food and Drug Administration.
Customers should review LiveO2’s current Intended Use, safety, and manufacturer guidance before purchase or use. Individuals with medical concerns should consult a qualified healthcare professional before beginning an exercise or oxygen-training program.
Before using any EWOT or Adaptive Contrast oxygen-training system, customers should review the manufacturer’s current intended-use guidance, setup instructions, safety warnings, operating precautions, and training resources.
LiveO2 states that its systems are intended for healthy adults participating in exercise training and recommends consulting a qualified healthcare professional before beginning an exercise program. Individuals with medical concerns or other health considerations should seek appropriate healthcare guidance before beginning Exercise with Oxygen Therapy (EWOT), simulated-altitude training, or Adaptive Contrast training.
If shortness of breath, unusual discomfort, or other concerning symptoms occur during use, discontinue the session and seek appropriate medical guidance.
*** For important health and safety information, please review SanaVi's Medical & Safety Disclaimer Page before using this equipment.
Manufacturer Information
LiveO2 was founded by electrical engineer Mark Squibb after health challenges affecting his family led him to investigate oxygen delivery and the limitations of conventional oxygen approaches. What began as an engineer-led effort to solve a practical problem eventually developed into an oxygen training company built around Adaptive Contrast, a method that alternates oxygen-rich and simulated-altitude breathing phases during structured exercise. LiveO2 presents its development as a process shaped by engineering, real-world testing, user experience, and continued refinement of its oxygen training systems.
Today, LiveO2 manufactures specialized oxygen training systems for home users, athletes, wellness-focused individuals, and professional environments such as clinics, studios, gyms, and performance facilities. The company supports its systems with the LiveO2 Training App, New User Coaching, setup guidance, instructional resources, protocol training, technical support, and customer care.
For SanaVi Health Systems, LiveO2 represents an important part of the Exercise with Oxygen Therapy category because its Adaptive Contrast technology expands beyond oxygen-only EWOT by incorporating alternating oxygen-rich and simulated-altitude breathing within structured exercise sessions.
Product Specifications & Manufacturer Updates
We make every reasonable effort to keep product information accurate. Because some products are updated or fulfilled directly by the manufacturer, specifications, included components, packaging, images, or minor design details may change without notice. If a material change affects an order, SanaVi will review the matter in good faith and work toward a reasonable resolution.
For more information, please see the Manufacturer Product Updates & Specification Changes section of our Terms of Service.
Regulatory Notices
LiveO2 positions its Adaptive Contrast EWOT systems around structured exercise, oxygen-rich breathing, simulated-altitude breathing phases, and general wellness and fitness applications. These systems are designed for Exercise with Oxygen Therapy (EWOT) and Adaptive Contrast training and are not intended for medical diagnosis, disease treatment, or medical oxygen use.
LiveO2 states that its systems are not intended to diagnose, treat, cure, prevent, or mitigate any disease or medical condition. LiveO2 identifies its products as exercise equipment rather than medical devices, and its current user guidance states that LiveO2 claims have not been evaluated by the U.S. Food and Drug Administration.
Customers should review LiveO2’s current Intended Use, safety, and manufacturer guidance before purchase or use. Individuals with medical concerns should consult a qualified healthcare professional before beginning an exercise or oxygen-training program.
Intended Use & Limitations
Before using any EWOT or Adaptive Contrast oxygen-training system, customers should review the manufacturer’s current intended-use guidance, setup instructions, safety warnings, operating precautions, and training resources.
LiveO2 states that its systems are intended for healthy adults participating in exercise training and recommends consulting a qualified healthcare professional before beginning an exercise program. Individuals with medical concerns or other health considerations should seek appropriate healthcare guidance before beginning Exercise with Oxygen Therapy (EWOT), simulated-altitude training, or Adaptive Contrast training.
If shortness of breath, unusual discomfort, or other concerning symptoms occur during use, discontinue the session and seek appropriate medical guidance.
*** For important health and safety information, please review SanaVi's Medical & Safety Disclaimer Page before using this equipment.
Related Education
Need help choosing the right system? Read our Exercise With Oxygen Therapy Systems Buying Guide for key comparison points, placement considerations, and practical buying guidance.
If you’d like to better understand how Exercise with Oxygen Therapy (EWOT) systems work, we’ve developed a comprehensive education section dedicated to oxygen training, practical application, and home or professional use. You can explore foundational overviews, deeper explanations of oxygen-enriched exercise and Adaptive Contrast, and guidance on how EWOT systems are integrated into wellness, recovery, performance, and clinic-based environments.
For broader wellness education, visit the SanaVi Journal Learning Center.
Exercise With Oxygen Therapy Systems Buying Guide
Need help choosing the right system? Read our Exercise With Oxygen Therapy Systems Buying Guide for key comparison points, placement considerations, and practical buying guidance.
SanaVi Journal Articles
If you’d like to better understand how Exercise with Oxygen Therapy (EWOT) systems work, we’ve developed a comprehensive education section dedicated to oxygen training, practical application, and home or professional use. You can explore foundational overviews, deeper explanations of oxygen-enriched exercise and Adaptive Contrast, and guidance on how EWOT systems are integrated into wellness, recovery, performance, and clinic-based environments.
For broader wellness education, visit the SanaVi Journal Learning Center.
STAY INFORMED
Wellness Knowledge, Delivered
Receive thoughtful wellness education,
practical buying guidance, and occasional SanaVi updates.